General Information: |
Title: | Stream chemistry and runoff
(ja)
河川水質と流量 |
Identifier: | JaLTER-Hokkaido-Kita.18.19 |
Abstract: |
We collected stream waters and measured the water levels at Dorokawa-river, Butokamabetsu-river, Akaishi-river, and M3-river in Uryu Experimental Forest with two weeks interval. In addition, we measured water levels continuously using automatic instruments. After bringing samples to the laboratory, we measured pH and electric conductivity (EC), and then filtered the water samples using glass filter (GF/F: 0.7μm) and kept it below 4oC prior to further chemical analysis. We analyzed the concentrations of ions (Cl-, NO3-, SO42-, Na+,NH4+,K+,Mg2+,Ca2+) by using ionchromatography (Dionex, DX-500, ICS-1100) after the additional filtering with a 0.2 μm membrane filter.
(ja)
雨龍研究林内の泥川(一本橋),ブトカマベツ川,赤石川,M3流域において採水および水位観測を2週間間隔で行った.また自動による水位の連続観測を行った.採取後、実験室に持ち帰り、pH, 電気伝導度(EC)を測定した。サンプル水はガラス繊維濾紙(GF/F: 0.7μm)を用いて速やかにろ過後,化学分析までの期間4℃以下で保存した.さらに0.2μmメンブレインフィルターでろ過後、ろ液のイオン成分(Cl-, NO3-, SO42-, Na+,NH4+, K+,Mg2+,Ca2+)をイオンクロマトグラフィー(Dionex, DX-500, ICS-1100)を用いて分析した。
|
Keywords: |
- stream water quality
(ja)
河川水質
- forest
(ja)
森林
- ion
(ja)
イオン成分
- runoff
(ja)
流量
- nitrate
(ja)
硝酸イオン
- pH
(ja)
pH
- electric conductivity
(ja)
電気伝導度
|
|
|
Involved Parties
Data Set Owners: |
Individual: | Karibu Fukuzawa
(ja)
福澤加里部 |
Organization: | Forest Research Station, Field Science Center for Northern Biosphere, Hokkaido University
(ja)
北海道大学北方生物圏フィールド科学センター森林圏ステーション |
Position: | Associate Professor
(ja)
准教授 |
Address: |
483 Otoineppu, |
Otoineppu, Hokkaido 098-2501 Japan |
(ja)
日本 098-2501 北海道 中川郡音威子府村 |
(ja)音威子府483 |
|
Phone:
|
+81-1656-5-3216 / 01656-5-3216 (voice) |
|
Phone:
|
+81-1656-5-3218 / 01656-5-3218 (fax) |
|
Email Address:
|
|
Web Address:
|
|
|
Data Set Contacts: |
Individual: | Karibu Fukuzawa
(ja)
福澤加里部 |
Organization: | Forest Research Station, Field Science Center for Northern Biosphere, Hokkaido University
(ja)
北海道大学北方生物圏フィールド科学センター森林圏ステーション |
Position: | Associate Professor
(ja)
准教授 |
Address: |
483 Otoineppu, |
Otoineppu, Hokkaido 098-2501 Japan |
(ja)
日本 098-2501 北海道 中川郡音威子府村 |
(ja)音威子府483 |
|
Phone:
|
+81-1656-5-3216 / 01656-5-3216 (voice) |
|
Phone:
|
+81-1656-5-3218 / 01656-5-3218 (fax) |
|
Email Address:
|
|
Web Address:
|
|
|
Data Set Characteristics
Geographic Region: |
Geographic Description: | A1 sampling point / A1採水地点 |
Bounding Coordinates:
|
West: | 142.259391199 degrees
|
East: | 142.259391199 degrees
|
North: | 44.3640234779 degrees
|
South: | 44.3640234779 degrees
|
|
Geographic Region: |
Geographic Description: | B1 sampling point / B1採水地点 |
Bounding Coordinates:
|
West: | 142.223844936 degrees
|
East: | 142.223844936 degrees
|
North: | 44.39439071 degrees
|
South: | 44.39439071 degrees
|
|
Geographic Region: |
Geographic Description: | D1 sampling point / D1採水地点 |
Bounding Coordinates:
|
West: | 142.202293799 degrees
|
East: | 142.202293799 degrees
|
North: | 44.3919466164 degrees
|
South: | 44.3919466164 degrees
|
|
Geographic Region: |
Geographic Description: | M3 sampling point / M3採水地点 |
Bounding Coordinates:
|
West: | 142.257177821 degrees
|
East: | 142.257177821 degrees
|
North: | 44.3557097667 degrees
|
South: | 44.3557097667 degrees
|
|
|
|
|
Sampling, Processing and Quality Control Methods
Step by Step Procedures
|
Step 1: |
Description:
|
Water Sampling / 採水
We collected water with two weeks interval during no-snow season. At M3 basin, we collected water upper stream of the V-noch weir. Then, we measured the temperature of the stream water.
(ja)
無雪期(6-11月)に2週間間隔で採水した。M3流域では、Vノッチ型量水堰の上流において採水した。また、採取時の水温を測定した。
|
|
Step 2: |
Description:
|
Measurement of water level / 水位測定
We measured water level with ten minutes interval automatically. At Dorokawa River, we set the water level sensor at the PVC pipe vertically established at the Ipponbashi bridge. At Butokamabetsu and Akaishi Rivers, we set the sensors at the stream bed. At M3 basin, we set the sensor at the stream bed of upper side of the weir.
(ja)
10分間隔で水位を自動測定した。
泥川では一本橋の橋桁に設置した塩ビパイプにて、ブトカマベツ川、赤石川では川底にて、M3流域では量水堰上流側の底にそれぞれ水位測定センサーを設置し、データロガーに保存したデータを定期的に回収した。
|
|
Step 3: |
Description:
|
Filterling and chemical analysis / ろ過と化学分析
After bringing to the laboratory, we measured pH and electric conductivity (EC). Then, we filtered water sample through glass fiber filter (Whatman, GF/F: 0.7μm) and stored below 4 degree-C until further processing. We analyzed the concentration of anion (Cl-, NO3-, SO42-) and cation (Na+, NH4+, K+, Mg2+, Ca2+) by using ion chromatography after the additional filtering with a 0.2 μm membrane filter.
(ja)
実験室に持ち帰り、pHと電気伝導度を測定した。その後ガラス繊維濾紙(ワットマン, GF/F: 0.7μm)を用いてろ過し、ろ液は分析までの期間4℃以下で保存した。さらに0.2μmメンブレインフィルターでろ過後、イオンクロマトグラフィーを用いて陰イオン(塩化物イオン,硝酸イオン,硫酸イオン)、陽イオン(ナトリウムイオン,アンモニウムイオン,カリウムイオン,マグネシウムイオン,カルシウムイオン)濃度を分析した。
|
Instrument(s):
| Ion chromatography (Dionex, DX-500, ICS-1100) / イオンクロマトグラフィー(Dionex, DX-500, ICS-1100) |
|
|
Data Set Usage Rights
Follows to Data Policy of JaLTER Network.
(ja)
JaLTERネットワークのデータポリシーに従う。 |
|