Data Set Citation:
When using this data, please cite the data package:
KISHIMOTO (.
Soil Respiration, AsiaFlux TKY site, 2005, Takayama, Japan; 土壌呼吸観測,アジアフラックスTKYサイト,2005, 高山(たかやま)
JaLTER-takayama-01.28.2 (https://db.cger.nies.go.jp/JaLTER/metacat/metacat/JaLTER-takayama-01.28.2/jalter-en)
General Information:
Title:Soil Respiration, AsiaFlux TKY site, 2005, Takayama, Japan; 土壌呼吸観測,アジアフラックスTKYサイト,2005, 高山(たかやま)
Identifier:JaLTER-takayama-01.28.2
Abstract:
  Soil Respiration in broad-leaf deciduous forest, AsiaFlux TKY site, Japan. Soil respiration was continuously measured in 1 ha plot using automatic open-closed chamber based on the open-flow IRGA method. アジアフラックスTKYサイト(落葉広葉樹林)の1 haプロットにおける土壌呼吸の連続観測。
Keywords:
  • Soil respiration
  • bload-leaf deciduous forest
  • 土壌呼吸
  • 落葉広葉樹林

Involved Parties

Data Set Owners:
Individual: (Mo. W) Ayaka KISHIMOTO
Organization:National Institute for Agro-Environmental Sciences
Email Address:
mow(at)niaes.affrc.go.jp
Data Set Contacts:
Individual: (Mo. W) Ayaka KISHIMOTO
Organization:National Institute for Agro-Environmental Sciences
Email Address:
mow(at)niaes.affrc.go.jp

Data Set Characteristics

Time Period:
Begin:
2005
End:
2005

Sampling, Processing and Quality Control Methods

Step by Step Procedures
Step 1:
Description:

Soil respiration

Measurement method:AOCC method: using automatic open-closed chamber based on the open-flow IRGA method (Steady state flow-through method)

Measuring system: AOCC system co-constructed with the investigators and JANS Co. Ltd.(Tokyo) and SENSA Co. Ltd. (Tokyo). Using PC for data logging and relay control; available for remote control and monitoring via LAN cable.

Instrument(s): 2-channel NDIR CO2 analyzer (BINOS 100, Germany)
Instrument(s): Flow control: Mass flow controllers at 1.35L min-1
Instrument(s): Chamber type: AOCC (Two-way air pressure driven open/close)
Sampling Area And Frequency:
CO2 efflux from soil surfaces was measured continuously on a secondary bload-leaf deciduous forest floor.
Sampling Description:
Continuous (only snow-free season); 60-min measuring cycle for 4 chambers, during each cycle every chamber should close for 30 minutes (first 15 min for purge and 15 min for measuring). Auto-calibration for CO2 analyzer for every 4 cycles.

Data Set Usage Rights

To open the data, mutually agreeable arrangement must be made a priori in regarding to (1) identification of the user(s), (2) purpose of the data usage, and (3) property rights.
Access Control:
Auth System:knb
Order:denyFirst
Metadata download: Ecological Metadata Language (EML) File