Data Set Citation:
When using this data, please cite the data package:
Fukuzawa K.
Stream chemistry
JaLTER-Hokkaido-Kita.295.10 (https://db.cger.nies.go.jp/JaLTER/metacat/metacat/JaLTER-Hokkaido-Kita.295.10/jalter-en)
General Information:
Title:Stream chemistry
(ja) 河川水質
Identifier:JaLTER-Hokkaido-Kita.295.10
Abstract:
We collected stream waters at the outlet of several watersheds in Uryu Experimental Forest. In each watershed, different forest management was conducted: clear-cutting, scarification, scarification with soil-replacement. Control(non-treatment) watershed was also established. After bringing samples to the laboratory, we measured pH and electric conductivity (EC), and then filtered the water samples using glass fiber filter (GF/F: 0.7μm) and kept it below 4 degree-C prior to further chemical analysis. We analyzed the concentrations of ions (Cl-, NO3-, SO42-, Na+,NH4+,K+,Mg2+,Ca2+) by using ionchromatography (Dionex, DX-500, ICS-1100) after the additional filtering with a 0.2 μm membrane filter. (ja) 雨龍研究林内の泥川上流域にある複数の集水域の出口において河川水を採水した.それぞれの集水域においては異なる森林施業:皆伐,ササ掻き起こし,表土戻しが行われた。何も処理を行わない対照区も設けられた。採取後、実験室に持ち帰り、pH, 電気伝導度(EC)を測定した。サンプル水はガラス繊維濾紙(GF/F: 0.7μm)を用いて速やかにろ過後,化学分析までの期間4℃以下で保存した.さらに0.2μmメンブレインフィルターでろ過後、ろ液のイオン成分(Cl-, NO3-, SO42-, Na+,NH4+, K+,Mg2+,Ca2+)をイオンクロマトグラフィー(Dionex, DX-500, ICS-1100)を用いて分析した。
Keywords:
  • stream water quality
    (ja) 河川水質
  • impact of forest management
    (ja) 森林施業の影響
  • forested watershed
    (ja) 森林集水域
  • ion
    (ja) イオン成分
  • nitrate
    (ja) 硝酸イオン
  • pH
    (ja) pH
  • electric conductivity
    (ja) 電気伝導度
Data Table, Image, and Other Data Details:
Metadata download: Ecological Metadata Language (EML) File
Data Table:Ion concentration data of stream water / 河川水のイオン濃度データ ( View Metadata | Download File download)
Data Table:pH and EC data of stream water / 河川水のpH, ECデータ ( View Metadata | Download File download)

Involved Parties

Data Set Owners:
Individual: Karibu Fukuzawa (ja) 福澤加里部
Organization:Forest Research Station, Field Science Center for Northern Biosphere, Hokkaido University
(ja) 北海道大学北方生物圏フィールド科学センター森林圏ステーション
Position:Assistant Professor
(ja) 助教
Address:
483 Otoineppu,
Otoineppu, Hokkaido 098-2501 Japan
(ja) 日本 098-2501 北海道 中川郡音威子府村
(ja)音威子府483
Phone:
+81-1656-5-3216 / 01656-5-3216 (voice)
Phone:
+81-1656-5-3218 / 01656-5-3218 (fax)
Email Address:
caribu@fsc.hokukdai.ac.jp
Web Address:
http://forest.fsc.hokudai.ac.jp/~exfor/fr/
Data Set Contacts:
Individual: Karibu Fukuzawa (ja) 福澤加里部
Organization:Forest Research Station, Field Science Center for Northern Biosphere, Hokkaido University
(ja) 北海道大学北方生物圏フィールド科学センター森林圏ステーション
Position:Assistant Professor
(ja) 助教
Address:
483 Otoineppu,
Otoineppu, Hokkaido 098-2501 Japan
(ja) 日本 098-2501 北海道 中川郡音威子府村
(ja)音威子府483
Phone:
+81-1656-5-3216 / 01656-5-3216 (voice)
Phone:
+81-1656-5-3218 / 01656-5-3218 (fax)
Email Address:
caribu@fsc.hokukdai.ac.jp
Web Address:
http://forest.fsc.hokudai.ac.jp/~exfor/fr/

Data Set Characteristics

Geographic Region:
Geographic Description:DE0 sampling point / DE0採水地点
Bounding Coordinates:
West:  142.203508632  degrees
East:  142.203508632  degrees
North:  44.418876993  degrees
South:  44.418876993  degrees
Geographic Region:
Geographic Description:DE1 sampling point / DE1採水地点
Bounding Coordinates:
West:  142.203876155  degrees
East:  142.203876155  degrees
North:  44.4204698591  degrees
South:  44.4204698591  degrees
Geographic Region:
Geographic Description:DE2 sampling point / DE2採水地点
Bounding Coordinates:
West:  142.205610643  degrees
East:  142.205610643  degrees
North:  44.4237739401  degrees
South:  44.4237739401  degrees
Geographic Region:
Geographic Description:DE3 sampling point / DE3採水地点
Bounding Coordinates:
West:  142.205589206  degrees
East:  142.205589206  degrees
North:  44.4243420436  degrees
South:  44.4243420436  degrees
Geographic Region:
Geographic Description:DE4 sampling point / DE4採水地点
Bounding Coordinates:
West:  142.205888206  degrees
East:  142.205888206  degrees
North:  44.4250811927  degrees
South:  44.4250811927  degrees
Geographic Region:
Geographic Description:DE5 sampling point / DE5採水地点
Bounding Coordinates:
West:  142.206424706  degrees
East:  142.206424706  degrees
North:  44.4280347127  degrees
South:  44.4280347127  degrees
Geographic Region:
Geographic Description:DE6 sampling point / DE6採水地点
Bounding Coordinates:
West:  142.207263454  degrees
East:  142.207263454  degrees
North:  44.4304365405  degrees
South:  44.4304365405  degrees
Geographic Region:
Geographic Description:DE7 sampling point / DE7採水地点
Bounding Coordinates:
West:  142.207622604  degrees
East:  142.207622604  degrees
North:  44.4315944515  degrees
South:  44.4315944515  degrees
Geographic Region:
Geographic Description:DE8 sampling point / DE8採水地点
Bounding Coordinates:
West:  142.206764696  degrees
East:  142.206764696  degrees
North:  44.430626047  degrees
South:  44.430626047  degrees
Geographic Region:
Geographic Description:DE9 sampling point / DE9採水地点
Bounding Coordinates:
West:  142.207859345  degrees
East:  142.207859345  degrees
North:  44.4349655905  degrees
South:  44.4349655905  degrees
Geographic Region:
Geographic Description:DEU sampling point / DEU採水地点
Bounding Coordinates:
West:  142.207446495  degrees
East:  142.207446495  degrees
North:  44.4315090835  degrees
South:  44.4315090835  degrees
Time Period:
Begin:
2003-04-01
End:
2016-03-31

Sampling, Processing and Quality Control Methods

Step by Step Procedures
Step 1:
Description:

Water Sampling / 採水

We collected water at the outlet of watersheds. Interval of the sampling during non-snowy season was 1-2 weeks until 2010, and then 1 month. During snowy season, the interval was 1 month.
(ja) 集水域末端にて河川水を採取した。サンプリング間隔(無雪期)は2010年までは1-2週間,2011年以降は1カ月間隔とした。積雪期には1カ月間隔とした。

Step 2:
Description:

Filterling and chemical analysis / ろ過と化学分析

After bringing to the laboratory, we measured pH and electric conductivity (EC). Then, we filtered water sample through glass fiber filter (Whatman, GF/F: 0.7μm) and stored below 4 degree-C until further processing. We analyzed the concentration of anion (Cl-, NO3-, SO42-) and cation (Na+, NH4+, K+, Mg2+, Ca2+) by using ion chromatography after the additional filtering with a 0.2 μm membrane filter.
(ja) 実験室に持ち帰り、pHと電気伝導度を測定した。その後ガラス繊維濾紙(ワットマン, GF/F: 0.7μm)を用いてろ過し、ろ液は分析までの期間4℃以下で保存した。さらに0.2μmメンブレインフィルターでろ過後、イオンクロマトグラフィーを用いて陰イオン(塩化物イオン,硝酸イオン,硫酸イオン)、陽イオン(ナトリウムイオン,アンモニウムイオン,カリウムイオン,マグネシウムイオン,カルシウムイオン)濃度を分析した。

Instrument(s): pH meter (DKK-TOA, HM-30V) EC meter (DKK-TOA, CM-30S) Ion chromatography (Dionex, DX-500, ICS-1100) / pH計(東亜ディーケーケー,HM-30V) EC計(東亜ディーケーケー,CM-30S) イオンクロマトグラフィー(Dionex, DX-500, ICS-1100)

Data Set Usage Rights

Follows to Data Policy of JaLTER Network.
(ja) JaLTERネットワークのデータポリシーに従う。
Access Control:
Auth System:JaLTER
Order:allowFirst
Allow: [read] public
Additional Metadata
Metadata download: Ecological Metadata Language (EML) File